Outdoor IV tester
Model:FT-PV31
Brand:fengtu
Related products
1.Product introduction of portable photovoltaic string tester
PV31 is our company's standard photovoltaic module IV curve tester, which can accurately detect the power generation efficiency and conversion rate of modules and strings within the 1500V range. It can quickly detect the working characteristics of photovoltaic strings under natural light. The equipment is simple to operate and easy to carry. It is equipped with a high-precision irradiation meter and temperature sensor, which can provide accurate on-site irradiation values and ambient temperature and other parameters.
PV31 portable photovoltaic string tester adopts integrated packaging technology, with clear function descriptions in Chinese and English operation interfaces, one-click detection data export, single module/string detection speed is completed in 10 seconds, fast, accurate and comprehensive detection functions can be used as a third-party The preferred configuration for testing institutions and power station operation and maintenance. The whole machine is equipped with a more high-precision capacitive/resistive load, as well as a faster radiometer operation module and corresponding IV curve analysis software, which can analyze the IV curve with higher definition and have continuous IV uninterrupted scanning. Advantages, assisting in the detection of photovoltaic power stations throughout the system.
2. Application fields of portable photovoltaic string tester
Single component test, string test, irradiation test, power generation test
3. Portable photovoltaic string tester can test performance indicators
Shadow occlusion, dust attenuation, STC contrast, fill factor, IV curve, maximum power, maximum power voltage
Maximum power current, irradiance, ambient temperature, module temperature, PV curve, conversion efficiency, power generation
4. Product advantages of portable photovoltaic string tester
1. 0~1500V high-precision curve test
Using our new resistive test module, single component detection is more accurate, and it can test the IV curve test of the maximum 1500V string and the series and parallel test of the 30A string.
2. STC nominal parameter conversion test
IV test matches more than 95% of the current photovoltaic panel specifications, switches component parameters of different specifications more quickly, and automatically calculates the current power generation efficiency and conversion rate of the panel, helping users know the real parameters of the components more accurately.
3. String test
Photovoltaic power station string testing can quickly test the power generation efficiency, short circuit, power generation, etc. of the entire photovoltaic string, and quickly screen the electrical performance between different strings, thereby classifying MPPT parameters, screening inverter string efficiency, and improving power generation of the power station. quantity.
4. Single component testing
The PV31 portable photovoltaic string tester has a unique module power generation testing function, which can adapt to the module qualification test stipulated in IEC61853 currently adopted in Europe and the United States, or be used for local lighting resource testing.
The tester provides a high-resolution test mode of up to 400 points and an Ethernet monitoring function that complies with the Modbus/tcp protocol to meet the needs of scientific research.
5. National standard industry benchmark
The equipment complies with international and industry implementation standards and can be used as a third-party measurement basis.
◎IEC 61215-2005 Crystalline silicon photovoltaic modules for ground use—Design identification and finalization
◎IEC 61646-2008 Specification for the design and qualification of thin-film batteries for ground use
◎CGC/GF003.1:2009 Technical Specifications for Acceptance of Grid-connected Photovoltaic Power Generation System Engineering Part 1: Electrical Equipment
◎GB4793.1-2007/IEC 60010-1 Safety requirements for electrical equipment for testing, control and laboratory use
◎IEC60904-2 2007 standard solar cell requirements
◎IEC60891-2009 Temperature and irradiance correction method for IV measured characteristics of photovoltaic devices
◎IEC61853-2011 Photovoltaic device performance testing and energy level
◎Passed CE and ROHS certification
◎According to the authoritative verification of the China Institute of Metrology, the voltage and current test accuracy is better than 0.2%, meeting and exceeding product index requirements.
6. Component barcode scanning function
The detection can be equipped with wireless scanning to enter component barcodes. PV31 detection data automatically matches component barcodes and can be printed accordingly, facilitating traceability and query.
7. Continuity test
PV31 can continuously test the IV data of photovoltaic cells, with automatic detection every 20 seconds, which can help users continuously monitor and compare the performance parameters of the components.
8. Power generation and radiation monitoring PR value
It can detect the cumulative power generation value of the current component/string in real time, and then compare the power generation value of the entire photovoltaic power station to estimate and calculate the PR value of the power station.
9. iV compensation function
It can truly support the outdoor verification of photovoltaic cells and adapt to the outdoor performance testing of photovoltaic cells in the experimental stage of engineering applications.
10. Environmental monitoring function
It has environmental detection functions such as ambient temperature detection, panel temperature detection, and solar irradiance detection, and can provide user-selectable irradiation meter matching.
11. Domestic configuration and international standard gold medal after-sales service
PV31 provides 24-hour fast after-sales service in China, and provides free software and hardware upgrade services.
12. Chinese and English operation interface
In response to different markets and different user needs, PV31 provides Chinese and English operation interfaces. The concise operation menu allows users to quickly master various functions of the instrument.
13. Long battery life
PV31 provides a built-in high-capacity lithium battery module, which can be easily replaced and has a continuous battery life of up to 8 hours to provide sufficient charging power for testing.
14. Range switching
For the current and voltage of components/strings of different specifications, PV31 can automatically switch the test range to provide a more accurate test range and provide overvoltage and overcurrent protection.
15. High expansion capacity
The PV31 internal unit can reliably store more than 2,000 test waveforms, and provides an SD card slot to support storage space expansion. Data can be synchronized to the host through USB to store data for PC software analysis.
16. Photovoltaic module correction database
It has a rich built-in solar cell component correction model database, covering products from most component manufacturers, providing a reference for the conversion ratio of test results and providing users with comprehensive parameter setting functions that can be added manually.
17. High voltage isolation design is safer
The equipment is equipped with a high-voltage bulkhead power supply design to provide users with reliable safety guarantees. The maximum open-circuit voltage test range can reach 1500V, and it provides photovoltaic array test functions up to 30KW.
18. 100 meters wireless communication
A wireless connection is used between the host and the probe, providing a maximum wireless connection function of 100 meters, making on-site testing more convenient and convenient.
19. Touch screen panel operation
The host operation panel adopts a touch screen plus keyboard operation method. The bright LCD screen can display more clearly under the sun. The whole machine contains rich peripheral connections and provides a variety of expanded online functions.
5. Detailed parameters of portable photovoltaic string tester
Test object | |||||
fill factor | IV curve | Maximum power | Maximum power voltage | ||
Component temperature | PV curve | Conversion efficiency | Power generation | ||
shadow occlusion | dust attenuation | STC comparison | short circuit current | ||
Maximum power current | radioactivity | ambient temperature | open circuit voltage | ||
Peak power point voltage, current |
Constant voltage point current |
Series resistance |
Parallel resistor | ||
Specifications | |||||
Category | numerical value | PV31 | |||
Voltage | Measuring range | 10V~1500V | |||
measurement accuracy | 0.1V | ||||
Test accuracy | ±0.5%±0.2V | ||||
current | Measuring range | 0.01A~30A | |||
measurement accuracy | 0.001A | ||||
Test accuracy | ±0.5%+0.02A | ||||
Maximum power test | Repeatability accuracy | ±0.5%±3W | |||
Maximum power test range | 50W~45KW | ||||
Convert to maximum power accuracy under STC | Better than ±5% | ||||
temperature | Ambient temperature measurement range | -30℃~100℃ | |||
Battery temperature measurement range | -30℃~100℃ | ||||
Temperature test accuracy | ±1℃ | ||||
radioactivity | Irradiance measurement range | 0~1800W/m2 | |||
Irradiance measurement accuracy | Better than ±3% | ||||
software | test period | 20s | |||
data point | 2048 points | ||||
data storage | >2000 value | ||||
continuity test | 20s | ||||
Barcode entry | Wireless code scanning/manual entry | ||||
Chinese and English interface | Universal | ||||
Photovoltaic module model database | Universal | ||||
Online expansion | Multiple IVs can be tested online for comparison | Universal | |||
Hardware parameters | |||||
Category | numerical value | PV31 | |||
Host parameters | Wireless transmission distance | 50 meters | |||
Expand storage | SD card | ||||
Display | 640x480, 6.5 inches LED | ||||
Power supply | Built-in lithium battery/power adapter | ||||
Battery parameters | 14.8V/4400mAH | ||||
Battery life | 8 hours | ||||
size | 390x300x200mm | ||||
weight | 5.8kg | ||||
Operating temperature | -10℃~50℃ | ||||
storage temperature | -20℃~60℃ | ||||
humidity | 5~95%RH | ||||
Radiometer parameters | interface | RS232 serial port, Bluetooth | |||
weight | 450g | ||||
power supply | 4 AAA batteries | ||||
Temperature Sensor | standard | temperature check | |||
Detection interface | Connecting line | MC4 |
6. Portable photovoltaic string tester accessories list
serial number | name | Specification | quantity | unit |
1 | Host | Instrument test host | 1 | tower |
2 | Radiometer | standard | 1 | tower |
3 | Radiometer stand | standard | 1 | tower |
4 | Temperature probe kit | Temperature Sensor | 1 | set |
5 | Power Adapter | standard | 1 | indivual |
6 | test suite | Banana head test lead + alligator pliers | 4 | root |
7 | MC4 one to two adapter | standard | 1 | indivual |
8 | User manual | standard | 1 | tower |
9 | After-sales information | Warranty card, certificate of conformity, etc. | 1 | set |
Related article
-
Forest fire weather station, intelligent fire prevention
2024-03-20 -
8m manual common lightning rod recommended
2024-05-09 -
Advantages of the box-type radar speedometer
2024-01-22 -
What is the Negative Oxygen Ion Monitoring System?
2024-02-22 -
How to protect the fully automatic weather station from lightning?
2024-03-08 -
Advantages of Negative Oxygen Ion Monitoring Stations
2024-03-12 -
Recommended Manufacturers of Portable Weather Stations
2024-03-15 -
Are field microclimate observatories useful?
2024-04-15