Product

Contact us

Shandong Fengtu IOT Technology Co., Ltd

Sales Manager:Ms. Emily Wang

Cel,Whatsapp,Wechat:+86 15898932201

Email:info@fengtutec.com

Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

location:Home>Products>Weather Sensor>Radiation Sensors>A four-component radiometer
A four-component radiometer

A four-component radiometer

Model:FT-FS7H

Brand:fengtu

A four-component radiometer is a high-precision instrument that calculates net radiation by directly measuring short - and long-wave radiation.

1.Product overview of four-component radiometer

A four-component radiometer is a high-precision instrument that calculates net radiation by directly measuring short - and long-wave radiation.In meteorological applications, infrared radiation or long-wave radiation refers to electromagnetic radiation with a wavelength greater than 3.0 μm. Longwave radiation is physically related to temperature and is emitted by all objects on Earth. The spectral range of the sun's shortwave radiation is 300nm ~ 3μm (accounting for 99.5% of the total solar radiation energy).

Fengtu's FT-FS7H four-component net radiation sensor directly measures daily long-wave radiation and short-wave radiation and calculates the net radiation amount. For meteorological observations of atmospheric radiation (radiation emitted by clouds/water vapor, carbon dioxide, etc.) and the net radiation exchange between the Earth and the atmosphere. Net total radiation (shortwave + longwave) is usually measured by 4 net pyranometers or a single net pyranometer (its detector can respond to the entire wavelength range). Pyranometers measure downward emitted longwave radiation using a detector with a hemisphere pointing upward. The net longwave radiation and the downward emitted radiation from the earth-atmosphere system can be calculated. It has been widely used in the fields of meteorology/photovoltaic/horticulture/agriculture and industry.

2. Product features of four-component radiometer

1. Comply with WMO World Meteorological Organization specifications (CIMO Guide)

2. Strong sensitivity to infrared radiation with a wavelength of 4~50µm

3. The heating effect of silicone cover has small error.

4. Cosine response error is small

5. Reduce environmental impact

6. Has better stability

3. Technical indicators of four-component radiometer

Technical ParametersTechnical Description
total radiation
grade standardsFIRST CLASS
Time response (95%)13s
Thermal radiation zero offset±10W/m2
Temperature change zero point offset±3W/m2
nonlinear±1.5%
instability±1%
directional response±18 W/m2
Spectral error±3%
Temperature response (-10~40℃)3%
tilt error±1%
Spectral response285~3000nm
Daily mining accuracy<5%
resolution1W/m2
Sensitivity7~14μV/W•m-2
Signal output0~20mV
earth radiation
Spectral response400~50000nm
Response time (sec)95%<18s
Non-stability (change/year)<2%
Temperature Coefficient≤±1%(-20℃~+50℃)
perspective180°
Sensitivity(µV/W/m²)2~150uV/Wm-2
Impedance(Ω)20~140
Window heating offset<4W/m2 (solar radiation 1000W/m2)
Signal range-500~+500 W/m²
Signal output-20~0mV
General parameters
Number of channels4 channels of mV, 2 channels of 4-wire platinum resistors
Temperature SensorWire type platinum resistor (JIS standard: c-1604-1989 category)
Operating temperature-40~+70℃
weight9kg